Description of the data path

MARLIN Technical Manual V2.4.0

74

Within this area, the R-G-B component values of the samples are added and
used as actual values for the feedback.

The following drawing illustrates the AUTOFNC_AOI settings in greater detail.

The algorithm is based on the assumption that the R-G-B component sums of
the samples shall be equal, i.e., it assumes that the mean of the sampled grid
pixels is to be monochrome.

Note

L

If the adjustment fails and the work area size and/or position
becomes invalid this feature is automatically switched off -
make sure to read back the ON_OFF flag if this feature doesn't
work as expected.

Figure 39: AUTOFNC_AOI positioning

AO
I: Y-
siz

e

AOI: X-size

AF_AREA_SIZE: Width: n x 128

A

F

_ARE

A_
S

IZ

E

:

H

eig

ht: n x

12

8

0,0

AF_AREA_POSITION: Left,Top

Sampling grid for Auto-Function