Error codes – ALLIED Vision Technologies Marlin F-201 User Manual
Page 232

Configuration of the camera
MARLIN Technical Manual V2.4.0
232
Store
To store the current camera settings into a profile:
1.
Write the desired ProfileID with the SaveProfile flag set.
2.
Read back the register and check the ErrorCode field.
Restore
To restore the settings from a previous stored profile:
1.
Write the desired ProfileID with the RestoreProfile flag set.
2.
Read back the register and check the ErrorCode field.
Set default
To set the default profile to be loaded on startup, reset or initialization
1.
Write the desired ProfileID with the SetDefaultID flag set.
2.
Read back the register and check the ErrorCode field.
Factory default
To go back to the factory default profile:
1.
Select ProfileID=0 and toggle the SetDefaultID flag set.
2.
Read back the register and check the ErrorCode field.
Error codes
Note
L
•
The default profile is the profile that is loaded on
power-up or an INITIALIZE command.
•
A save or load operation delays the response of the
camera until the operation is completed. At a time only
one operation can be performed.
ErrorCode #
Description
0x00
No error
0x01
Profile data corrupted
0x02
Camera not idle during restore operation
0x03
Feature not available (feature not present)
0x04
Profile doesn’t exist
0x05
ProfileID out of range
0x06
Restoring the default profile failed
0x07
Loading LUT data failed
0x08
Storing LUT data failed
Table 129: User profile: Error codes