The cameras also have an advanced register which allows even more precise
image capture delay after receiving a hardware trigger.

Trigger delay advanced register

The advanced register allows the start of the integration to be delayed by
max. 2

21

µs, which is max. 2.1 s after a trigger edge was detected.

Register

Name

Field

Bit

Description

0xF0F00834

TRIGGER_DELAY

Presence_Inq

[0]

Presence of this feature:

0: N/A

1:Available

Abs_Control

[1]

Absolute value control

O: Control with value in the
value field

1: Control with value in the
absolute value CSR. If this
bit=1 the value in the value
field has to be ignored.

---

[2..5]

Reserved

ON_OFF

[6]

Write ON or OFF this feature

ON=1 Read: Status of the
feature

OFF=0

---

[7..19]

Reserved

Value

[20..31]

Value

Table 21: Trigger Delay CSR

Register

Name

Field

Bit

Description

0xF1000400

TRIGGER_DELAY

Presence_Inq

[0]

Indicates presence of this
feature (read only)

---

[1..5]

Reserved

ON_OFF

[6]

Trigger delay on/off

---

[7..10]

Reserved

DelayTime

[11..31]

Delay time in µs

Table 22: Trigger delay advanced CSR