Sequence control – ALLIED Vision Technologies Marlin F-201 User Manual
Page 212
Configuration of the camera
MARLIN Technical Manual V2.4.0
212
Sequence control
It is possible to make certain settings for a sequence of images beforehand
by using this register.
Register
Name
Field
Bit
Description
0xF1000220
SEQUENCE_CTRL
Presence_Inq
[0]
Indicates presence of this
feature (read only)
---
[1..4]
Reserved
AutoRewind
[5]
ON_OFF
[6]
Enable/Disable this feature
---
[7..15]
Reserved
MaxLength
[16..23] Maximum possible length of a
sequence (read only)
SeqLength
[24..31] Length of the sequence
0xF1000224
SEQUENCE_PARAM
---
[0..4]
Reserved
ApplyParameters
[5]
Apply settings to selected
image of sequence; auto-reset
IncImageNo
[6]
Increment ImageNo after
ApplyParameters has finished
---
[7..23]
Reserved
ImageNo
[24..31] Number of image within a
sequence
Table 106: Sequence control register