Advanced register: trigger counter
The trigger counter feature is controlled by the following advanced feature
register:
Having this feature enabled, the current trigger counter value (external trig-
ger seen by hardware) will be inserted as a 32-bit integer value into any cap-
tured image.
Setting the Reset flag to 1 resets the trigger counter to 0 – the Reset flag
is self-cleared.
The ON_OFF and LinePos fields are simply mirrors of the time stamp feature.
Settings of these fields are applied to all image stamp features.
Additionally there is a register for direct read out of the trigger counter
value.
Register
Name
Field
Bit
Description
0xF1000620 TRGCNT_STAMP
Presence_Inq
[0]
Indicates presence of this
feature (read only)
Reset
[1]
Reset trigger counter
---
[2..5]
Reserved
ON_OFF
[6]
SIS (time stamp) on/off
---
[7]
Reserved
---
[8..15]
Reserved
LinePos
[16..31]
Line position of SIS
(time stamp)
0xF1000624 TRGCNT
[0..31]
Trigger counter
Table 127: Advanced register: Trigger counter