beautypg.com

Parameter update timing – ALLIED Vision Technologies Marlin F-201 User Manual

Page 103

background image

Description of the data path

MARLIN Technical Manual V2.4.0

103

Parameter update timing

MARLIN cameras show the following timing behavior:

Frame rate or transfer rate is always constant (precondition:
shutter

< transfer time)

The delay from shutter update until the change takes place: up to 3
frames.

Figure 60: MARLIN update timing

on page 103 demonstrates

this behavior. It shows that the camera receives a shutter update com-
mand while the sensor is currently integrating (Sync is low) with shutter
setting 400. The camera continues to integrate and this image is output
with the next FVal. The shutter change command becomes effective with
the next falling edge of sync and finally the image taken with shutter
200 is output with a considerable delay.

Parameters that are sent to the camera faster than the max. frame rate
per second are stored in a FIFO and are activated in consecutive images.

Principally a Marlin camera is not able to recognize how many parameter the
user will change. Due to the fact that communication between host and cam-
era is asynchronous, it may happen that one part of parameter changes is
done in image n+1 and the other part is done in image n+2.

Figure 60: MARLIN update timing

Shutter Update Command

Current Charge Time

Sync

FVal

400

200

integrates image
with

with shutter eg 400

continues integrating

outputs image

with shutter 400

outputs image

with shutter 200

shutter 200

This manual is related to the following products: