beautypg.com

ALLIED Vision Technologies Marlin F-201 User Manual

Page 112

background image

Description of the data path

MARLIN Technical Manual V2.4.0

112

To read data:

1.

Query RDRD flag (buffer ready?) and write the number of bytes the host
wants to read to RBUF_CNT.

2.

Read the number of bytes pending in the receive buffer RBUF_ST (more
data in the buffer than the host wanted to read?) and the number of
bytes left for reading from the receive FIFO in RBUF_CNT (host wanted
to read more data than were in the buffer?).

3.

Read received characters from SIO_DATA_REGISTER, beginning at char 0.

4.

To input more characters, repeat from step 1.

To write data:

1.

Query TDRD flag (buffer ready?) and write the number of bytes to send
(copied from SIO register to transmit FIFO) to TBUF_CNT.

2.

Read the available data space left in TBUF_ST (if the buffer can hold
more bytes than are to be transmitted) and number of bytes written to
transmit buffer in TBUF_CNT (if more data is to be transmitted than fits
in the buffer).

3.

Write character to SIO_DATA_REGISTER, beginning at char 0.

4.

To output more characters, repeat from step 1.

Note

L

Contact your local dealer if you require further informa-
tion or additional test programs or software.

AVT recommends the use of Hyperterminal™ or other
communication programs to test the functionality of
this feature. Alternatively use SmartView to try out this
feature.

This manual is related to the following products: