Menu Operation
134
corner when menu is off
ΔY
----
Displays the difference
value between Y1 and Y2
cursors
Time Cursor Measurement
Press CURSOR
→Mode to display the CURSOR menu and
select the Manual mode. Press the Type softkey to select
Time measurement.
Softkey
Options
Description
Mode
Manual
Manual cursor measurement
Auto
Auto cursor measurement
Track
Track cursor measurement
Source
CH1
Measure CH1
CH2
Measure CH1
MATH
Measure MATH
Type
Voltage
Measure voltage value
Time
Measure time value
X1--
X2--
Press this softkey to select X1,
X2, or both X1 and X2 cursors
for adjustment.
Current time values for X1 and
X2 are displayed in the softkey