beautypg.com

Franklin Fueling Systems TS-DTU Data Transfer Unit Dispenser Retrofit Manual User Manual

Page 34

background image

34

Wayne Vista 2 - DTU Installation

24. Using wire nuts provided, connect the incoming

power, one end of the wire with the ferrite, and a
wire for the DTU power.

Figure 11: Connect Wires

25. Use tie-wrap to attach connections together.

Figure 12: Wrap Wires

26. Attach wiring from power wiring harness to the

side of the display assembly using adhesive
backed anchor and wire tie.

Figure 13: Attach Power Wiring Harness

27. Close display assembly and fi rmly attach using

two screws. Ensure that all wiring is free of sharp
edges and pinching when doors close. If sharp
edges or pinching is observes, use additional tie
wraps and anchors to reroute wiring as necessary.

28. Attach ring terminal of ground wire to dispenser

bracket using screw and nut as shown. Wind
excess wiring and fi rmly attach with tie wraps to
ensure that it does not interfere with door closing.

29. Find straight conduit fi tting and fl exible conduit

from IS conduit kit, 020-1513. Remove nut and
bushing from straight conduit fi tting. Push bushing
on one end of fl exible conduit. Pull wires from
nipple assembly through bushing / fl exible conduit
and attach fl exible conduit to straight conduit fi tting
using nut.

Figure 14: Attach Flexible Conduit

30. Remove nut and bushing from the 90-degree

conduit fi tting and feed fl exible conduit through
nut. Put bushing on unattached end of fl exible
conduit. Pull wires from fl exible conduit through
the 90-degree conduit fi tting and pull excess wire
into DTU. Use nut to attach fl exible conduit to
90-degree fi tting.

Figure 15: Flexible Conduit DTU Connection

31. Cut excess wire inside DTU allowing a length of 2”

for terminal block wiring. Strip wire insulation 3/8”
from the end of the wire.