Gilbarco Advantage Narrow Frame - DTU Installation

26. Find reducer from IS wiring kit, 020-1513. From

electrical enclosure, pull wires from potted nipple
assembly through 3/4” opening of reducer and
attach reducer to the top of the nipple assembly.

27. Find straight conduit fi tting from IS wiring kit,

020-1513. From electrical enclosure, pull wires
from the potted nipple assembly through opening
of straight conduit fi tting. Attach straight conduit
fi tting onto the reducer.

28. Remove nut and bushing from straight conduit

fi tting. Place bushing on one end of fl exible
conduit. Push wires from nipple assembly through
bushing / fl exible conduit and secure fl exible
conduit to straight conduit fi tting using nut.

Figure 12: Attaching Flexible Conduit

29. Remove nut and bushing from 90 degree conduit

fi tting and push fl exible conduit through nut. Put
bushing on unattached end of fl exible conduit.
Push wires from fl exible conduit through the 90
degree conduit fi tting and pull excess wire into
DTU. Attach fl exible conduit to 90-degree fi tting
with nut.

Figure 13: Attach Flexible Conduit to DTU

30. Cut excess wire inside DTU allowing a length of 2”

for terminal block wiring. Strip insulation

3

/

8

” from

ends of wire. Attach wires to DTU terminal block
as follows (DIAGRAM)

Figure 14: Attach Wiring to DTU

31. Reinstall barrier cover using screws that were

removed in step 23.

32. Replace DTU cover.

33. Install the DTU assembly on the horizontal cross

bracket as shown in Figure 15. Use the two
screws, washers, and nuts as supplied in the TS-
DTU/P hardware kit.

Figure 15: Attach DTU Mounting Bracket

34. Find input connector on AC distribution wiring

harness and disconnect.

35. Insert new power harness with ferrites between

input power and AC distribution harness.

Figure 16: Connecting to Dispenser Power