beautypg.com

Html operation, Chapter five, Mkp 3000 series – Extron Electronics MKP 3000 Series User Manual

Page 38

background image

MKP 3000 Series • SIS

Operation

SIS

Operation, cont’d

MKP 3000 Series

5

Chapter Five

HTML Operation

Downloading the Startup Page

Viewing System Status

Using the Configuration Pages

Using the File Management Page

Saving and Restoring a Configuration

Special Characters

4-16

Command/r

esponse table for MKP SIS commands (continued)

Command

ASCII Command

Response

Additional description

(host to

M

K

P

)

(M

K

P

to host)

IP setup, continued

Switch W

eb page priority

Esc

X2

7

Cpag

Iwp

X2

7

Read W

eb page priority

Esc

Cpag

X2

7

Set verbose mode

Esc

X1

CV

V

rb

X1

Set MKP

to r

eport changes from other sources.

Read verbose mode

Esc

CV

X1

Read the verbose mode.

Read connection’s security level

Esc

CK

X1

0

Backup and r

estore unit configuration

Save unit configuration

Esc

1*

{config type} XF

Cfg 1

* {config type}

{config type} = 2 = unit-specific parameters

(box.config) such as global pr

eset names, audio/

video input and output names. The files ar

e stor

ed

in the dir

ectory /nortxe-backup, cr

eated on the

unit by the Save commands.

Restor

e unit configuration

Esc

0 * {config type} XF

Cfg 1

*

{config type}