Mounting the mkp 3000 l, Mounting the mkp 3000 l in a lectern, Mounting the mkp 3000 l in a rack – Extron Electronics MKP 3000 Series User Manual
Page 13: Ul requirements for rack mounting, Installation, cont’d, Po w er re se t
MKP 3000 Series • Installation
MKP 3000 Series • Installation
Installation, cont’d
2.
Cable the MKP and any AAPs within the UCM panel (see
“Rear Panel and Side Panel Connections,” later in this
chapter).
3.
Align the UCM panel in the rack, and secure it using the
remaining screws.
Extr
on
PO
W
ER
RE
SE
T
I/O
SELEC
T
BA
CK
CANCEL
1
2
3
4
5
6
7
8
9
0
VID
EO
GR
EE
N
AU
DIO
RE
D
TA
KE
OU
TP
UT
IN
PU
T
MK
P
30
00
L
Extron
MKP 3000 L
Extron
UCM-RAAP
Figure 2-6 — Mounting the MKP 3000 L to the
UCM RAAP and a rack
UL requirements for rack mounting
The following Underwriters Laboratories (UL) requirements
pertain to the installation of the MKP 3000 L into a rack.
1.
Elevated operating ambient temperature
— If the
equipment is installed in a closed or multiunit rack
assembly, the operating ambient temperature of the rack
environment may be greater than room ambient.
Therefore, consider installing the equipment in an
environment compatible with the maximum ambient
temperature (Tma) specified by the manufacturer. For the
MKP 3000, the Tma is 122 °F (50 °C).
2.
Reduced air flow
— Installation of the equipment in a
rack should be such that the amount of air flow required
for safe operation of the equipment is not compromised.
2-9
3
.
Mount the MKP’s faceplate to the mud ring or wall box
with machine screws (figure 2-5).
Extr
on
MK
P 30
00
I/O
SE
LE
CT
PO
W
ER
RE
SE
T
Figure 2-5 — Mounting the MKP to the wall box
4
.
Reconnect the power supply and restore power.
Mounting the MKP 3000 L
You can mount the MKP 3000 L in a lectern or other furniture, or
you can mount it in a rack using the UCM RAAP controller
mounting kit.
Mounting the MKP 3000 L in a lectern
To mount the MKP 3000 L in a lectern or other furniture,
1
.
Using the MKP 3000 L cut-out template in appendix A,
measure and mark guidelines for the opening in the
furniture.
2
.
Cut out the furniture material from the marked area.
3
.
Check the opening size by inserting the MKP into it.
Enlarge and/or smooth the edges of the opening as
needed.
4
.
Complete all necessary cabling, and, with power
disconnected at the source, insert the MKP into the
opening.
5
.
Fasten the MKP directly to the furniture using four #8 or
#10 screws or 10-penny nails.
Mounting the MKP 3000 L in a rack
To mount the MKP 3000 L in a rack using the UCM RAAP,
1
.
Attach the MKP 3000 L to the UCM RAAP using the four
flat Philips head machine screws provided with the UCM.
2-8