Perform a soft reset of the MKP as follows:

1

.

Press and hold the Reset (R) button until the Reset LED
blinks once (events reset), twice (IP system reset), or three
times (absolute reset) (figure 3-9).

R

R

R

R

R

R

R

R

R

6
seconds

LED flashes

twice.

3
seconds

LED flashes

once.

Press and hold
the Reset button.

Release, then
immediately
press and
release again.

Release, then
immediately
press and
release again.

Release, then
immediately
press and
release again.

Absolute

(mode 5)

Reset

Press and hold
the Reset button.

IP System

(Mode 4)

Reset

Press and hold
the Reset button.

Events

(Mode 3)

Reset

9
seconds

LED flashes

three times.

Figure 3-9 — Performing soft resets

2

.

Release the Reset button and then immediately press and
release the Reset button again. Nothing happens if the
second momentary press does not occur within 1 second.

Performing a hard reset

The hard reset restores the MKP to the original factory default
firmware configuration and erases all user-installed software or
firmware. (A hard reset does not perform all possible MKP
reset functions.)

CAUTION

Ensure that you have backed up any locally-created
HTML, JavaScript, or other files that you have
uploaded to the MKP’s user file space before you
perform the hard reset. A hard reset will erase all
locally-created files from the MKP.

Perform a hard reset as follows:

1

.

If necessary, turn off power to the switcher.

2

.

Press and hold the Reset button on the rear panel while
you apply AC power to the MKP (figure 3-10).

R

R

Press and hold the
Reset button while you
apply power to the MKP.

The LED flashes
on and off.

Release the Reset button.

Power

12 VDC
Power Supply

Figure 3-10 — Performing a hard reset

3-19