Ethernet (lan) port, Ethernet connection, Default ip parameters – Extron Electronics MPX Plus 866 A Rev. B User Manual

Page 88: Ethernet connection -4 default ip parameters -4, Preliminar y, Programming and control, cont’d

background image

SIS

Programming and Control, cont’d

MPX Plus 866 A Media Presentation Matrix Switcher • SIS Programming and Control

4-4

PRELIMINAR

Y

Ethernet (LAN) Port

The rear panel LAN connector on the switcher can be connected to an Ethernet

LAN or WAN, making makes SIS control of the switcher possible. Communication

between the switcher and the controlling device is via Telnet (a TCP socket using

port 23). The Telnet port can be changed, if necessary, via SIS. The SIS commands

and behavior of the product are identical to the commands and behavior the

product exhibits when you are communicating with it via a serial port.

Ethernet connection

The Ethernet cable can be terminated as a straight-through cable or a crossover

cable and must be properly terminated for your application (figure 4-3).

Crossover cable — Direct connection between the computer and the

MPX switcher

Patch (straight) cable — Connection of the MPX switcher to an Ethernet LAN

A cable that is wired as T568A at one end
and T568B at the other (Tx and Rx pairs
reversed) is a "crossover" cable.

A cable wired the same at both ends is
called a "straight-through" cable, because
no pin/pair assignments are swapped.

12345678

RJ-45

Connector

Insert Twisted

Pair Wires

Pins:

Crossover Cable

Straight-through Cable

Pin

1

2
3
4
5
6
7
8

Wire color

White-green

Green
White-orange
Blue
White-blue
Orange
White-brown
Brown

Wire color

T568A

T568B

End 1

End 2

End 1

End 2

White-orange

Orange
White-green
Blue
White-blue
Green
White-brown
Brown

Pin

1

2
3
4
5
6
7
8

Wire color

White-orange

White-green

Blue

White-blue

White-brown

Brown

Wire color

T568B

T568B

White-orange

Orange

Orange

White-green

Blue

White-blue
Green

Green

White-brown

Brown

Figure 4-3 — RJ-45 Ethernet connector pin assignments

Default IP parameters

To access the switcher via the Ethernet port, you need the Extron IP address and

may need the subnet mask and the gateway address. If the IP address has been

changed to an address comprised of words and characters, you can determine the

actual numeric IP address using the ping (ICMP) utility (see appendix A, “Ethernet

Connection”, for more details). If the addresses have not been changed, the factory-

specified defaults are:

• IP address

192.168.254.254

• Gateway address 0.0.0.0

• Subnet mask

255.255.0.0

• DHCP

off