beautypg.com

Ethernet link, Ethernet connection, Default address – Extron Electronics MPX Plus 866 A Rev. B User Manual

Page 190: Preliminar y

background image

MPX Plus 866 A Media Presentation Matrix Switcher • Ethernet Connection

A-2

Ethernet Connection

PRELIMINAR

Y

Ethernet Link

The rear panel Ethernet connector on the switcher can be

connected to an Ethernet LAN or WAN. This connection

makes SIS control of the switcher possible using a computer

connected to the same LAN.

Ethernet connection

The Ethernet cable can be terminated as a straight-through cable or a crossover

cable and must be properly terminated for your application (figure A-1).

Crossover cable — Direct connection between the computer and the switcher
Patch (straight-through) cable — Connection of the switcher to an Ethernet

LAN

A cable that is wired as T568A at one end
and T568B at the other (Tx and Rx pairs
reversed) is a "crossover" cable.

A cable wired the same at both ends is
called a "straight-through" cable, because
no pin/pair assignments are swapped.

12345678

RJ-45

Connector

Insert Twisted

Pair Wires

Pins:

Crossover Cable

Straight-through Cable

Pin

1

2
3
4
5
6
7
8

Wire color

White-green

Green
White-orange
Blue
White-blue
Orange
White-brown
Brown

Wire color

T568A

T568B

End 1

End 2

End 1

End 2

White-orange

Orange
White-green
Blue
White-blue
Green
White-brown
Brown

Pin

1

2
3
4
5
6
7
8

Wire color

White-orange

White-green

Blue

White-blue

White-brown

Brown

Wire color

T568B

T568B

White-orange

Orange

Orange

White-green

Blue

White-blue
Green

Green

White-brown

Brown

Figure A-1 — RJ-45 connector pinout tables

Default address

To access the switcher via the LAN port, you need the switcher’s IP address. If the

address has been changed to an address comprised of words and characters, you

can determine the actual numeric IP address using the Ping utility. If the address

has not been changed, the factory-specified default is 192.168.254.254.
Ping can also be used to test the Ethernet link to the switcher.

A

CT

L

IN

K

E

T

H

E

R

N

E

T