Design rule verification

You can inadvertently recall a combination of partial presets that causes an

overload. The user-selected design rule verification function analyzes and

compares all presets.
Execute the design rule verification function by clicking Tools > Design Rule
Verification

.

After verification, if no combination of presets that would cause an overload

is detected, the function prepares an on-screen report stating “

The current

configuration has been successfully verified“.
On the other hand, if, after verification, a problem is detected, the function

prepares an on-screen report stating “

Overload Possible” and lists the specific

errors that it found. This combination of partial presets, if recalled, will cause an

overload. To prevent a possible overload, you need to make adjustments to your

partial presets. Run the design rule verification utility again to ensure that you

have resolved the potential problem.

N

Extron recommends performing a design rule verification before pushing a

configuration to the switcher and frequently while designing partial presets to
ensure that the DSP will not be overloaded.

If you are in Live mode (connected to a switcher) and any presets exist in the MPX

switcher that are not present in the DSP Configurator program (indicated by an

asterisk next to the preset name), the function halts and prompts the user to run a

backup

.

Backup (click File > Backup) transfers all partial presets plus the current

configuration from the switcher to a DSP configuration file within the

DSP Configurator program and then prompts you to save the file to your hard

drive. Backup is unavailable when the DSP Configurator program is in Emulate