GE Industrial Solutions Entellisys 5.0 User Manual User Manual
GE Industrial Solutions Equipment
Table of contents
Document Outline
- 1.1 Description of operation 13
- 1.2 Switchgear installations 14
- 1.3 System components 15
- 2.1 Environmental 29
- 2.2 Type tests 29
- 2.3 Approvals 30
- 3.1 Entellisys HMI Overview 31
- 3.2 Job Documentation 35
- 3.3 Controlling circuit breakers 36
- 4.1 Basic metering 39
- 4.2 Expanded metering 39
- 4.3 Demand metering 40
- 4.4 Harmonics metering 41
- 4.5 Metering accuracy 42
- 4.6 Setup 43
- 4.7 Usage 47
- 4.8 Demand Metering Alarms 54
- 4.9 Troubleshooting 56
- 5.1 Overcurrent protection 57
- 5.2 Additional Relay Protection Packages 68
- 5.3 Advanced Protection Relays 88
- 5.4 Synch Check relay 105
- 7.1 Bus Differential Relay 115
- 7.2 Multi-Source Ground-Fault Relay 119
- 7.3 PT Throw-Over 125
- 7.4 Zone Selective Interlock 129
- 7.5 Ground Fault Tripping priority 136
- 8.1 Operation 140
- 8.2 Administration 146
- 8.3 Alarms and Events 150
- 8.4 FlexLogic™ Configuration 152
- 8.5 Troubleshooting 154
- 9.1 Sequence of Events Viewer 155
- 9.2 Waveform capture 159
- 9.3 High Current Trigger relay 163
- 10.1 Discrete inputs/outputs 167
- 11.1 Introduction to FlexLogic 185
- 11.2 FlexLogic rules 195
- 11.3 FlexLogic evaluation 196
- 11.4 FlexLogic Equation Editor 196
- 11.5 FlexLogic equation viewer 196
- 11.6 FlexLogic timers 197
- 11.7 FlexLogic virtual inputs 197
- 11.8 FlexLogic virtual outputs 198
- 11.9 FlexLogic circuit breaker commands 198
- 11.10 FlexLogic control alarms 199
- 11.11 Load FlexLogic equation 199
- 11.12 Save FlexLogic equation 199
- 11.13 FlexLogic example 199
- 11.14 FlexLogic redundancy 206
- 12.1 Viewing and understanding PM data 209
- 12.2 Adjusting preventive maintenance values 213
- 13.1 Use 215
- 13.2 Setup 217
- 13.3 Troubleshooting 219
- 14.1 Monitoring system health 221
- 14.2 Troubleshooting 224
- 15.1 Features 225
- 15.2 Bus & CPT 225
- 15.3 UPS compartment 226
- 15.4 Roof 227
- 15.5 Instrument and circuit breaker compartments 227
- A.1 Sequence of events cause code cross reference index 229
- A.2 Alarms and events description and system troubleshooting guide 258
- System architecture
- 1.1 Description of operation
- 1.2 Switchgear installations
- 1.3 System components
- 1.3.1 EntelliGuard circuit breaker
- 1.3.2 EntelliGuard E circuit breaker
- 1.3.3 Current transformers
- 1.3.4 Potential transformers
- 1.3.5 EntelliGuard Messenger
- 1.3.6 Compartment ID button
- 1.3.7 Messenger communications network
- 1.3.8 Messenger switch
- 1.3.9 CPU
- 1.3.10 Synch clock
- 1.3.11 Discrete I/O
- 1.3.12 System interface Ethernet communication network
- 1.3.13 System interface Ethernet switch
- 1.3.14 Touchscreen HMI
- 1.3.15 Remote HMI
- 1.3.16 VPN firewall device
- 1.3.17 Control power
- 1.3.18 UPS
- 1.3.19 UPS to HMI connection
- 1.3.20 RS-232 to RS-485 converter
- 1.3.21 Entellisys System Test Kit
- 1.3.22 Clamp circuit
- Specifications
- HMI Basics
- Metering
- Single-point functions
- 5.1 Overcurrent protection
- 5.2 Additional Relay Protection Packages
- 5.3 Advanced Protection Relays
- 5.4 Synch Check relay
- Zones, buses, and topologies
- Multi-point functions
- Reduced Energy Let-Thru Mode
- Sequence of events, fault reports and waveform capture records
- Discrete I/O
- 10.1 Discrete inputs/outputs
- 10.1.1 Hardware
- 10.1.2 Software
- 10.1.3 Setup
- 10.1.3.1 Wiring
- 10.1.3.2 I/O points direction
- 10.1.3.3 Input configuration
- 10.1.3.4 Output configuration
- 10.1.3.5 Operation
- 10.1.3.6 Contact input states
- 10.1.3.7 Contact output states
- 10.1.3.8 Test mode
- 10.1.3.9 Input test mode
- 10.1.3.10 Output test mode
- 10.1.3.11 Events
- 10.1.3.12 Configuration events
- 10.1.3.13 Confirmation events
- 10.1.3.14 Operation events
- 10.1.4 Troubleshooting
- 10.2 IEC 61850 - GOOSE I/O
- 10.1 Discrete inputs/outputs
- FlexLogic™
- 11.1 Introduction to FlexLogic
- 11.2 FlexLogic rules
- 11.3 FlexLogic evaluation
- 11.4 FlexLogic Equation Editor
- 11.5 FlexLogic equation viewer
- 11.6 FlexLogic timers
- 11.7 FlexLogic virtual inputs
- 11.8 FlexLogic virtual outputs
- 11.9 FlexLogic circuit breaker commands
- 11.10 FlexLogic control alarms
- 11.11 Load FlexLogic equation
- 11.12 Save FlexLogic equation
- 11.13 FlexLogic example
- 11.14 FlexLogic redundancy
- Preventive maintenance
- Alarms
- System health
- Control power and UPS configuration
- Alarms and events
- A.1 Sequence of events cause code cross reference index
- A.2 Alarms and events description and system troubleshooting guide
- A.2.1 HMI Internal Operations
- A.2.2 Commands from HMI
- A.2.3 HMI/CPU Communications Events
- A.2.4 CPU Settings Related Events
- A.2.5 CPU Status Events
- A.2.6 Breaker Command and Control Events
- A.2.7 Breaker Status Events
- A.2.8 Protection Relay Events
- A.2.9 Messenger/Breaker Config Status Events
- A.2.10 Preventative Maintenance Events