20 32khz power down mode +w32k, 1 description, 2 syntax – Rainbow Electronics 900 User Manual
Page 23: 3 defined values, 21 set alert tone command +tmel, 32khz power down mode +w32k, Set alert tone command +tmel

FLYFOT-M260-MODULE
Page: 23 / 239
This document is the sole and exclusive property of FLYFOT. Not to be distributed or divulged
without prior written agreement.
0:close power.
1:open power.
“IND”: indication control mode
b32 … b4 b3 b2 b1
CSQ
CBC
CREG
UNUSED
m : this value has 4 octets. If the bit is set, the value of indication unsolicited once changing.
Otherwise the value is not given until requested.
4.20 32kHz Power down Mode +W32K
4.20.1 Description
:
This specific command allows the 32kHz power down mode to be enabled or disabled.
Note :
z
When power down mode is entered, the product uses a 32kHz internal clock during
inactivity stages (despite of its nominal internal clock).
z
When enabled, power down mode is active after 1 to 15 minutes. The mode is not stored
in EEPROM : the command has to be repeated after a reset.
4.20.2 Syntax :
Command syntax : AT+W32K=
Command
Possible responses
AT+W32K=1
OK
Note : Enable 32kHz power down mode
Note : 32kHz power down mode is
enabled
AT+W32K=0
OK
Note : Disable 32kHz power down mode
Note : 32kHz power down mode is
disabled
4.20.3 Defined
values
1 : Enable 32kHz power down mode
4.21 Set alert tone Command +TMEL
4.21.1 Description:
This command with two parameters is used to set call active alert tone or other alert tone.