16 data / commands multiplexing +wmux, 1 description, 2 syntax – Rainbow Electronics 900 User Manual
Page 154: 3 defined values, 17 request identification information i, Data / commands multiplexing +wmux, 17 request, Identification information i

FLYFOT-M260-MODULE
Page: 154 / 239
This document is the sole and exclusive property of FLYFOT. Not to be distributed or divulged without
prior written agreement.
15.16 Data / Commands Multiplexing +WMUX
15.16.1 Description
This specific command allows to manage the data / AT commands multiplexing mode. See appendix
18.7 for the Data / Commands multiplexing protocol description.
15.16.2 Syntax
Command syntax AT+WMUX=
Command
Possible responses
AT+WMUX=?
+WMUX: (0-1)
OK
AT+WMUX?
+WMUX: 0
OK
Note : Data / Commands multiplexing
disabled.
AT+WMUX=1
Note : Enable Data / Commands multiplexing.
OK
15.16.3 Defined values
0: Multiplexing disabled. When the product is online (data communication in progress), no AT command
can be used (default).
1: Multiplexing enabled. Data flows and AT commands are multiplexed while in online mode (data
communication in progress).
15.17 Request identification information I
15.17.1 Description :
This command causes the product to transmit one or more lines of specific information text.
15.17.2 Syntax :
Command syntax : ATI
Command
Possible responses
ATI0
Note : Manufacturer and model
identifications
FLYFOT MODEM
MULTIBAND 900 1800
OK
Note : GSM 900 MHz primary band
ATI3 Note : Revision identification
FLYFOT M260-VER-01.00 Aug 12 2006