18.20 FLYFOT Scan +WSCAN
18.20.1 Description :
This specific command displays the received signal strength indication (
for a specified frequency (in absolute format).
This command is not allowed during communication.
18.20.2 Syntax :
Command syntax: AT+WSCAN=
Response syntax: +WSCAN:
Command
Possible responses
AT+WSCAN=50
Note : Request
+WSCAN: 23
OK
Note :
AT+WSCAN=1025
Note : Request power of absolute frequency 1025
CME ERROR: 3
Note : 1025 is not a valid absolute frequency
18.20.3 Defined values
0 : -113 dBm or less
1 : -111 dBm
2-30 : -109 to -53 dBm
31 : -51dBm or more
99 : not known or not detectable
18.21 FLYFOT Ring Indicator Mode +WRIM
18.21.1 Description :
This specific command sets the state of the Ring Indicator Mode.
z
In pulse RI mode : an electrical pulse is sent on the Ring Indicator signal just before sending any
unsolicited AT response, in order to lose no AT responses when client tasks are in sleep state. Still
in RI mode, when receiving incoming calls, electrical pulses are sent on the RI signal.
z
In up-down RI mode : no pulses are sent before unsolicited AT response. Up-down signals are sent
when receiving an incoming call.
18.21.2 Syntax :
Command syntax: AT+WRIM=
Command
Possible responses
AT+WRIM=
OK
AT+WRIM=0
OK
Note : Select up-down RI mode
Note : up-down RI mode selected