3 defined values, 17 alarm management +cala, 1 description – Rainbow Electronics 900 User Manual
Page 21: 2 syntax, 17 alarm, Management, Cala

FLYFOT-M260-MODULE
Page: 21 / 239
This document is the sole and exclusive property of FLYFOT. Not to be distributed or divulged
without prior written agreement.
AT+CCLK=”00/06/09,17:33:00+32”
Note : set date to June 9
th
, 2000, and time to
5:33pm, GMT +8
OK
Note : Date/Time stored
AT+CCLK=”00/13/13,12:00:00-16”
Note : Incorrect month entered
+CME ERROR 3
AT+CCLK?
Note : Get current date and time
+CCLK: “00/06/09,17:34:00+16”
OK
Note : current date is June 9
th
, 2000 current time
is 5:34:00 pm, GMT +4
AT+ CCLK =?
AT+ CCLK
+CME ERROR 3
Note: not support
4.16.3 Defined
values
:
String format for date/time is: “yy/MM/dd,hh:mm:ss±zz”.
Valid years are 00 (for 2000) to 98 (for 2098).
Default date/time is “00/01/01,00:00:00+00” (January 1
st
, 2000 / midnight).
4.17 Alarm Management +CALA
4.17.1 Description
:
This command is used to set alarms date/time in the ME. The maximum
number of alarms is 1.
4.17.2 Syntax
:
Command
syntax
:
AT+CALA=
AT+CALA=” ” (delete alarm)
Command
Possible responses
AT+CALA=”00/06/09,07:30”
Note : set an alarm for June 9
th
, 2000 at 7:30 am
OK
Note : Alarm stored
AT+CALA=”99/03/05,13:00:00”
Note : set an alarm for March 5
th
, 1999 at 1:00 pm
+CME ERROR 3
Note : Invalid alarm (date/time expired)
AT+CALA?
Note : list all alarms
+CALA: “00/06/08,15:25:00”
CALA interruption
+CALA: “00/06/08,15:25:00”
Note : an alarm occurs
AT+CALA=””
Note : delete this alarm.
OK
Note : Alarm is deleted
AT+CALA?
Note : list all alarms
+CALA: “00/06/09,07:30:00”
Note : Only one alarm
AT+CALA = ?
OK
AT+CALA
+CME ERROR 3
Note: not support