3 defined values, 18 select type of address +csta, 1 description – Rainbow Electronics 900 User Manual
Page 22: 2 syntax, 19 open micorphone power +tcfg, Select type of address +csta, Open micorphone power +tcfg

FLYFOT-M260-MODULE
Page: 22 / 239
This document is the sole and exclusive property of FLYFOT. Not to be distributed or divulged
without prior written agreement.
4.17.3 Defined
values
:
String format for alarms : “yy/MM/dd,hh:mm:ss” (see +CCLK).
Note : Seconds are not taken into account.
4.18 Select type of address +CSTA
4.18.1 Description
:
This command is used to select type of address.
4.18.2 Syntax
:
Command syntax :AT+CSTA=
Command
Possible responses
AT+CSTA?
+CSTA: 129
OK
Note : read current value
AT+CSTA=?
+CSTA: (129,145)
OK
Note : get all value
AT+CSTA=129
OK
Note : set value
AT+CSTA
+CME ERROR: 3
Note : not support
4.18.3
4.19 Open Micorphone power +TCFG
4.19.1 Description
:
Firstly this command is used to open or close main microphone power by parameter “RED”.
Secondly this command is used to control display mode by parameter “IND”.
4.19.2 Syntax
:
Command syntax : AT+TCFG=
Command
Possible responses
AT+TCFG=”IND”,1
Note : enable the value of CSQ、CREG、CBC、
CGREG indication unsolicited
OK
AT+TCFG=?
Note : Get all value
+TCFG: ("RED","NTC","IND"),(0,1)
OK
AT+TCFG?
AT+TCFG
+CME ERROR: 3
Note : not support
4.19.3 Defined
values
:
“RED”: record mode.