beautypg.com

Rainbow Electronics DS2154 User Manual

Page 57

background image

DS2154

031197 57/69

DS2154 TRANSMIT DATA FLOW Figure 13–11

TSER

TLINK

TS1 TO TS16

AIS

GENERATION

TRANSMIT SIGNALLING

ALL ONES

(TCR1.2)

TPOS,

TNEG

TAF

TNAF

TIMESLOT 0

PASS–THROUGH

(TCR1.6)

Si BIT INSERTION

CONTROL

(TCR1.3)

Sa BIT INSERTION

CONTROL (TCR2.3

THRU TCR2.7)

IDLE CODE/CHANNEL

SIGNALING BIT

CRC4 ENABLE

(CCR.4)

TRANSMIT UNFRAMED
ALL ONES (TCR1.4) OR

AUTO AIS (CCR2.5)

CODE WORD

GENERATION

AIS

GENERATION

0

0

0

0

0

0

1

1

1

1

1

1

1

INSERTION CONTROL

TIDR

TIR FUNCTION SELECT

0

1

RSER

(note 1)

(CCR3.5)

INSERTION CONTROL

VIA TIR1/2/3/4

TCBR1/2/3/4

TCR1.5

CCR3.6

CRC4 MULTIFRAME

ALIGNMENT WORD

GENERATION(CCR1.4)

E–BIT GENERATION

(TCR2.1)

AUTO REMOTE

ALARM GENERATION

(CCR2.4)

0

RECEIVE SIDE

CRC4 ERROR

DETECTOR

0

0

1

1

Sa BIT INSERTION

CONTROL REGISTER

(TSaCR)

1

TSiAF

TSiNAF

TRA

TSa4 to TSa8

KEY

= REGISTER

= DEVICE PIN

= SELECTOR

0

PER–CHANNEL CODE

GENERATION

(TCC1/2/3/4)

&

TDATA

TC1 TO TC32

DS0 MONITOR

NOTES:

1. TCLK should be tied to RCLK and TSYNC should be tied to RFSYNC for data to be properly sourced from RSER.
2. Auto Remote Alarm if enabled will only overwrite bit 3 of timeslot 0 in the Non Align Frames if the alarm needs

to be sent.