beautypg.com

Spi interrupt mask register – Rainbow Electronics AT75C310 User Manual

Page 114

background image

AT75C310

114

MODF: Mode Fault Interrupt Disable

0 = No effect.

1 = Disables the Mode Fault Interrupt.

OVRES: Overrun Error Interrupt Disable

0 = No effect.

1 = Disables the Overrun Error Interrupt.

SPI Interrupt Mask Register

Register Name:

SP_IMR

Access Type:

Read-only

RDRF: Receive Data Register Full Interrupt Mask

0 = Receive Data Register Full Interrupt is disabled.

1 = Receive Data Register Full Interrupt is enabled.

TDRE: Transmit Data Register Empty Interrupt Mask

0 = Transmit Data Register Empty Interrupt is disabled.

1 = Transmit Data Register Empty Interrupt is enabled.

MODF: Mode Fault Interrupt Mask

0 = Mode Fault Interrupt is disabled.

1 = Mode Fault Interrupt is enabled.

OVRES: Overrun Error Interrupt Mask

0 = Overrun Error Interrupt is disabled.

1 = Overrun Error Interrupt is enabled.

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

OVRES

MODF

TDRE

RDRF