Printronix P7000 H-Series Cartridge Ribbon Printer User Manual
Page 165

Fault Messages
165
INTERRUPT UNUSED
VECTOR 00
No
The controller board
receives an interrupt it does
not understand. The problem
can be created by electrical
noise, by a software
problem, or by a hardware
problem.
Cycle power. If this message
occurred once and never again,
you can ignore it. If the message
reappears or appears
consistently, contact your
authorized service
representative.
1
INVALID ACTIVATE
No
Printer detects a twinax
protocol communication
error.
Contact your authorized service
representative.
1
INVALID COMMAND
No
Printer detects a twinax
protocol communication
error and reports the error.
Contact your authorized service
representative.
1
LOADING PROGRAM
FROM PORT XX%
No
Status message: the new
emulation program is loading
into printer RAM. XX%
indicates how much of the
program has loaded.
No action is required.
LOADING PROGRAM
INTO FLASH
No
The printer has deleted the
previous program from flash
memory and is loading the
new program into flash
memory.
No action is required.
NEW SPX DETECTED
PRESS ENTER
No
The printer detects an SPX
installed at the debug port
and the SPX is valid for the
printer.
Contact your authorized service
representative.
1
NON VOLATILE
MEMORY FAILED
No
Large emulations reduce the
amount of space available
for saving configurations,
which means that
sometimes fewer than eight
configurations can be saved.
Contact your authorized service
representative.
1
ON LINE
N/A
Printer state message:
printer is online and in
communication with host.
No action is required.
ONLINE
28 CU NOT ENAB
Yes
Controller Unit Not Enabled.
Poll
time-out error. The printer
was not polled for one
minute across a coax
interface.
Check cable connection and
host system.
ONLINE
8344 FAILED*
No
Link-level code test detects
hardware failure.
Contact your authorized service
representative.
1
Table 10. LCD Message Troubleshooting Table
Displayed Message
Can User
Correct?
Explanation
Solution