Rs-422 – Printronix P7000 H-Series Cartridge Ribbon Printer User Manual
Page 123
RS-422
123
Clear To Send (CTS).
Status signal to the printer indicating the host is ready
to receive data/status signals from the printer.
Data Set Ready (DSR).
Status signal to the printer indicating the host is in a
ready condition.
Data Carrier Detect (DCD).
Status signal to the printer. The ON condition is
required for the printer to receive data.
Data Terminal Ready (DTR).
Control signal from the printer. Subject to
configuration.
RS-422
+RD, -RD
.Serial data stream differentially received by printer.
+TD, -TD
.Differentially driven serial data stream for transmitting status and
control information to the host. Subject to protocol selection.
NOTE:
±
RD
and
±
TD
form signal and return paths of a differential line signal.
Table 8. PSA3 RS-422 Serial Interface Connector Pin Assignments
Input Signals
Output Signals
Miscellaneous
Signal
Pin
Signal
Pin
Signal
Pin
- Receive Data
(-RD)
1
- Transmit Data
(-TD)
3
Chassis/Signal
Ground
5
+ Receive Data
(+RD)
6
+ Transmit Data
(+TD)
8