Fault Messages
161
E34 TRACE CMPLT
See User Manual
Yes
An illegal or unsupported
instruction was attempted in
the application program.
1.
Cycle Power. Run the
print job again. If the
message appears, load
the latest emulation
software.
2.
Cycle power. Run the
print job again. If the
message appears,
record the display
message and send it to
your next higher support
facility.
E99 UNKNOWN INT
See User Manual
Yes
An illegal or unsupported
instruction was attempted in
the application program.
1.
Cycle Power. Run the
print job again. If the
message appears, load
the latest emulation
software.
2.
Cycle power. Run the
print job again. If the
message appears,
record the display
message and send it to
your next higher support
facility.
E Net Test Unavailable
Yes
The ethernet PCBA did not
initialize correctly.
Cycle power. Wait for “E Net
Ready” to display, then retry
operation. If it still fails, contact
your authorized service
representative.
1
ERROR: CPLD NOT
PROGRAMMED
No
The Complex Programmable
Logic Device (CPLD) on the
controller board is not
programmed. The EC
cannot read the version bits
in the CPLD which tell the
EC which configuration
version is installed.
Contact your authorized service
representative.
1
ERROR: DC
PROGRAM NOT
VALID
Yes
The printer cannot find the
data controller program or
the validation checksum is
corrupt.
Download the program again. If
the message appears, contact
your authorized service
representative.
1
Table 10. LCD Message Troubleshooting Table
Displayed Message
Can User
Correct?
Explanation
Solution