beautypg.com

5 how to select and to modify parameters, 6 how to reset the default values, 7 osd settings – EVS XSense Version 10.04 - January 2011 Configuration Manual User Manual

Page 53: 1 genlock error msg, Lues, Enlock, Rror

background image

Issue
10.04.B

XSense – Version 10.04 – Configuration Manual

EVS Broadcast Equipment – January 2011

44

3.5 HOW TO SELECT AND TO MODIFY

PARAMETERS

To modify the parameters, you can proceed as follows for most of the parameters:

1.

Go to the desired page as explained in the Section 3.4.

2.

Select the parameter to be modified by pressing the corresponding F_ key.

3.

Make adjustment by rotating the jog dial.

4.

Press the corresponding F_ key again to validate the modification.

5.

Press MENU to return to the main page of the Setup menu.

3.6 HOW TO RESET THE DEFAULT VALUES

To restore the default value of a parameter in the Setup menu, proceed as follows:

1.

Go to the desired page as explained in the Section 3.4.

2.

Press CLEAR and the F_ key that corresponds to the parameter on which
to restore the default values. Confirm the action.

To restore the default values on the entire Setup menu, press CLEAR + F0 and
confirm the action.

3.7 OSD SETTINGS


OSD Settings p.1.1
[F1]Genlock Error Msg: Yes
[F2]Disk Error Msg : Yes
[F3]Network Error Msg: Yes
[F4]Cue number on OSD: Yes
[F5]Keyword info : No

[Menu]Quit [Clr+F_]Dft [F9]PgUp [F0]PgDn

3.7.1 G

ENLOCK

E

RROR

M

SG

Possible values: Yes (default) / No

This function enables or disables the Genlock information on the output monitor. If
Genlock reference is not correct, the !GkV message appears on the output
monitor.