8

R

ESET

A

RCHIVE

S

TATUS

:

Pressing F6 will reset the archive status of all clips present on the system. A

confirmation is required. Refer to the description of the Archive function for
details.

2.2.6 R

ECORD

T

RAINS

C

ONTINUOUS LOOP REC

This setting is read-only in the setup configuration window. It corresponds to the
value assigned to the Loop Rec setting for the related configuration in the
AVCFG.

R

ESYNC TO

TC

REF

You can also define this setting on page 2.1 of the setup menu on the Remote
Panel. You will find a description of this setting in the Multicam user manual.

2.2.7 VGA

S

ETTINGS

You can also define the VGA and RMT Sync setting on page 6.2 of the setup

menu on the Remote Panel. You will find a description of these settings in the
Multicam user manual.

2.2.8 VGA

&

RMT

S

YNC

Possible values: No, Yes, Server Nbr

This parameter selects whether and how the current clips machine, page and bank
of VGA screens and EVS Remote Panel must be synchronized.

Value Meaning

No (Default)

Clip machine, page and bank can be selected independently on
the VGA screen and on the EVS Remote Panel.

Yes

Clip machine, page and bank are synchronized between VGA
screen and EVS Remote Panel. Connecting to the clips of a
network machine or coming back to the clips of the local machine,
or selecting a new page or bank on one side will be automatically
reflected on the other.

Server Nbr

Clip pages and banks can be selected independently on VGA and
remote, but connecting to the clips of a network machine or

coming back to the clips of the local machine on the VGA or
Remote Panel will automatically reflect on the other.