Figure 41 clockwise/ counter-clockwise rotation, Config, Errors e10 – Parker Hannifin 88-021610-01G User Manual
Page 99
Parker Hannifin
Chapter 6 Command Reference 99
Rotary Motors
—Positive values represent
clockwise motion and negative values represent
counter-clockwise motion (assuming CMDDIR = Ø,
and that you connected the feedback device
according to instructions provided in “
” and “
”).
Figure 41 Clockwise/
Counter-clockwise rotation
CONFIG
Configuration Errors and Warnings
Type
Error Handling
Product Rev
Syntax
Aries 1.0
Units
N/A
Range
N/A
Default
N/A
Response
CONFIG <*>No
Errors
See Also
The CONFIG command gives a text-based status report of current
configuration errors and warnings (EØ through E24).
Error
Resolution
EØ—Motor Configuration
Warning
The motor rating is too high for the drive, and the
drive is using its own limits for safety reasons.
E1—Motor Configuration Error
One of the motor parameters is set to zero (0).
Look at the additional errors to find which
parameters are set at zero (0). Refer to your
motor specifications for the correct value.
E3—Max Inductance = Ø
This parameter is set to zero (0). To correct the
error, you must set a non-zero (0) value. Refer to
your motor specifications for the correct value.
(DMTIND)
E4—Rated Speed = Ø
This parameter is set to zero (0). To correct the
error, you must set a non-zero value. Refer to
your motor specifications for the correct value.
(DMTW)
E5—DPOLE = Ø
(DPOLE)
E6—Resistance = Ø
This parameter is set to zero (0). To correct the
error, you must set a non-zero value. Refer to
your motor specifications for the correct value.
(DMTRES)
E7—Ke = Ø
E8—Continuous Current = Ø