beautypg.com

Table 47 error log, Enable/disable, Estore – Parker Hannifin 88-021610-01G User Manual

Page 132: Alphabeti, Table 47

background image

Parker Hannifin

132 Aries User Guide

Bit

Function

0

Enable/Disable (Hardware enable input or software DRIVE command)

1

Bridge Fault

2

No PWM output (H-bridge switching)

3

Over Voltage (DC bus)

4

Under Voltage (DC bus)

5

Startup Voltage (analog command voltage)

6

Drive Over Temperature

7

Motor Over Temperature (calculated by thermal model)

8

Motor Thermal Switch

9

Feedback Error

10

Hall Error

11

Motor Configuration Error

12

Regeneration Fault

13-15

Reserved

Table 47 Error Log

Enable/Disable

ESTORE

Store smart encoder data

Type

Motor configuration

Product Rev

Syntax

ESTORE

Aries 1.0

Units

N/A

Range

N/A

Default

0

Response

<*>Storing
<*>Stored

See Also

Motor configuration commands

The ESTORE command is used to store all relevant motor configuration data

to the smart encoder. If changes are made to the motor configuration (for
example, if the current loop gains are tuned higher for the application), you
can store the changes by typing ESTORE into the terminal and pressing
Enter

.

The drive responds with Storing, and then Stored once the parameters have
been stored. After a reset, the new values are read from the encoder.

Note:

The ESTORE command stores the following parameters in the encoder:

DMTD, DMTIC, DMTIND, DMTINF, DMTJ, DMTKE, DMTLIM, DMTR,
DMTRES, DMTRWC, DMTSCL, DMTSWT, DMTTCW, DMTTWM, DMTW,

DMVLIM, DPOLE, DPWM, DTHERM, ENCOFF, ENCPOL, IGAIN,

INTLIM, PGAIN, P163.