Table 5 environmental specifications, ar-13xx, Cabinet cooling – Parker Hannifin 88-021610-01G User Manual
Page 23
Parker Hannifin
Chapter 2 Mechanical Installation 23
Environmental Specifications
(AR-01xx, AR-02xx, AR-04xx,
AR-08xx, AR-20xE, and AR-30xE)
Operating Temperature,
Maximum
Ambient Air
45°C (113°F)
Minimum 0°C
(32°F)
Storage Temperature
–40°C to 85°C (–40°F to 185°F)
Humidity
0 to 95%, non-condensing
Shock
15g, 11 ms half-sine
Vibration
10 to 2000 Hz at 2g
Pollution Degree
2 (per IEC 61010)
Installation Category
2 (per IEC 61010)
Table 4 Environmental Specifications, AR-01xx through AR-08xx, AR-20xE and AR-30xE
Environmental Specifications
(AR-13xx)
Operating Temperature,
Maximum
Ambient Air
40°C (104°F)
Minimum 0°C
(32°F)
Storage Temperature
–40°C to 85°C (–40°F to 185°F)
Humidity
0 to 95%, non-condensing
Shock
15g, 11 ms half-sine
Vibration
10 to 2000 Hz at 2g
Pollution Degree
2 (per IEC 61010)
Installation Category
2 (per IEC 61010)
Table 5 Environmental Specifications, AR-13xx
Cabinet Cooling
For cabinet cooling calculations, use Table 6 and Table 7 to determine the
power dissipation per drive.
AR-02xx
The power dissipation in Table 6 for the AR-02xx has been measured using
the Parker BE231D motor.