Parker Hannifin 88-021610-01G User Manual
Page 70
Parker Hannifin
70 Aries User Guide
Inputs—Enable, Reset
The drive Enable and Reset inputs are optically isolated inputs. Current is
limited internally for input voltage control of 5 to 24 volt logic. The Anode (+)
and Cathode (
−) are on separate connector pins to allow significant flexibility
in wiring to different styles of interface.
Description
Min
Max
Units
Turn-on time
–
1
ms
Turn-off time
–
1
ms
Guaranteed on voltage
4
–
VDC
Guaranteed off voltage
–
2
VDC
Maximum forward voltage
–
30
VDC
Maximum reverse voltage
-30
–
VDC
Forward current
3
12
mA
Note:
All parameters are at the connector pin.
Table 30 Inputs—Enable and Reset Electrical/Timing Characteristics
Outputs—Encoder
Description
Min
Typical
Max
Units
Output Frequency
(pre-quadrature)
5
MHz
Input Voltage High *
2.4
V
Input Voltage Low *
0.5
V
* Based on 120Ω differential load impedance.
Note:
All parameters are at the connector pin.
Note:
Aries encoder is a hardware pass-through; therefore, you cannot change output
resolution.
Table 31 Outputs—Encoder Outputs Electrical/Timing Characteristics
Outputs—Fault
Description
Min
Typical
Max
Units
Blocking Voltage
30
V
Continuous Load Current
10
mA
Output Saturation Voltage
(at 1.0 mA)
1.0
V
* Based on 120Ω differential load impedance.
Note:
All parameters are at the connector pin.
Table 32 Outputs— Fault outputs Electrical/Timing Characteristics