beautypg.com

Dmvscl, Dnotad – Parker Hannifin 88-021610-01G User Manual

Page 119

background image

Parker Hannifin

Chapter 6 Command Reference 119

DMVSCL

Velocity Scaling

Type

Drive Configuration

Product Rev

Syntax

DMVSCL

Aries 2.0

Units

Rotary motor: r = revolutions/second
Linear motor: r = meters/second

Range

Ш.ШШ to 4ШШ.ШШ (motor/drive dependent): ±Ш.Ш1

Default

4.ØØ

Response

DMVSCL: <*>1ШШ.Ш

See Also

DMODE

,

DMTR

Auto-Setup

: When using a Parker motor and the Aries Support Tool, this

command is automatically set for the selected motor.
If you did not use the Aries Support Tool, are using non-Parker motors, or
sent an RFS command to the drive, the parameter is set to 4.00—you must
manually set this parameter

to a non-zero number.

For a list of auto-configured commands, see

DMTR

.

The DMVSCL command scales the velocity command input. This command is
only valid in Velocity mode (

DMODE

4). It sets the full-scale velocity that will be

produced from a 10-volt input command. It controls the gain applied to the
input. This can be used to scale the input to match application needs. For
example, if an application requires a maximum speed of 10 Rev/Sec, then
the DMVSCL could be set to 10. This would scale the input to 1Rev/Sec for

every volt applied to the input.

DNOTAD

Notch Filter A Depth

Type

Tuning

Product Rev

Syntax

DNOTAD

Aries 2.0

Units

n/a

Range

Ш.ШШШШ - 1.ШШШШ

Default

Ш.ШШШШ (depth is zero)

Response

DNOTAD: *DNOTAD.5

See Also

DMODE

,

DNOTAF

,

DNOTAQ

,

DNOTBD

,

DNOTBF

,

DNOTBQ, DNOTLD

,

DNOTLG

The DNOTAD command sets the depth for the commanded torque/force notch

filter A. Setting this to zero (0) disables the filter. This command is useful in
adjusting the maximum allowable attenuation and phase shift through the
filter. The deeper the notch depth, the more attenuation and phase shift. In
general, the notch depth is increased until the resonance is diminished.
Increasing the depth further, might increase the phase shift to an
unacceptable level and decrease the overall system performance.

There are two cascaded notch filters labeled “A” and “B”. Both filters operate
in exactly the same way. The diagram below shows the topology of these
filters.