beautypg.com

Error messages, The ena – Parker Hannifin 88-021610-01G User Manual

Page 160

background image

Parker Hannifin

160 Aries User Guide

Error

Resolution

Invalid COM port number

Select a different COM port

Unable to open COM port

No COM port has been specified, or the
COM port is being used by other software.
Select a different COM port.

No response from Aries
drive

Power is not supplied to the drive, the drive
is not powered up, the power connection is
mis-wired, or the RS-232/485 cable is mis-
wired.
Check the drive to verify that the power
supply is connected, wired correctly. Then
apply power to the drive. Verify the wiring on
the RS-232/485 cable.

Incorrect response from
Aries drive

A different drive or serial device might be
connected to the selected COM port.
Verify that an Aries drive is connected to the
selected COM port.

OS needs to be
downloaded

Download the operating system to the Aries
drive.

Cycle power and
download OS

The Aries drive has encountered an error
while downloading an operating system.
Cycle power to the drive and download the
operating system again.

Table 49 Communications Port Errors and Resolutions

Error Messages

If the drive will not enable, you can view full-text reports of the drive
configuration (EØ through E24) and drive errors (E25 through E46). In a
terminal emulator, type CONFIG or ERROR, depending which information you

want to view.

You can also view the errors using the Aries Support Tool software.

► In

the

Menu

, select Status Panel. You can view the errors under Bit

Status

.

The following is a list of Error messages and a brief corrective action: