44 Aries User Guide

Output Power Connection

Figure 17 shows how to connect the motor cable to the drive. Use the screw
terminal connector that is installed in the drive. Current Parker motor cables
are marked with white numbers to indicate the phases. Connect Motor Phase
1 Æ U, 2 Æ V, and 3 Æ W, and Motor Safety Earth to the Protective Earth
ground connector.

Figure 17 Output Power Connection

Table 18 contains information for making connections with Parker Hannifin
motors.

Phase

Hi-Flex/ PS/

Gemini

Legacy Parker

Hannifin

Legacy MaxPlus

U

1

Red/Yellow

Red

V

2

White/Yellow

Black

W

3

Black/Yellow

Blue

Green/Yellow

Green/Yellow

Green

Table 18 Wiring to Motors

Note:

On models AR-20xE and AR-30xE, the Motor Brake Relay is on a

separate connector. See Figure 22 on page

50

.

Note:

See additional warning on next page.

Warning —

You must connect the Motor Safety Earth conductor terminal,

marked with the earth symbol , to the motor cable’s motor-safety-earth wire
(green/yellow).