Table 18 wiring to motors, Figure 17 output power connection, Output power connection – Parker Hannifin 88-021610-01G User Manual
Page 44
Parker Hannifin
44 Aries User Guide
Output Power Connection
Figure 17 shows how to connect the motor cable to the drive. Use the screw
terminal connector that is installed in the drive. Current Parker motor cables
are marked with white numbers to indicate the phases. Connect Motor Phase
1 Æ U, 2 Æ V, and 3 Æ W, and Motor Safety Earth to the Protective Earth
ground connector.
Figure 17 Output Power Connection
Table 18 contains information for making connections with Parker Hannifin
motors.
Phase
Hi-Flex/ PS/
Gemini
Legacy Parker
Hannifin
Legacy MaxPlus
U
1
Red/Yellow
Red
V
2
White/Yellow
Black
W
3
Black/Yellow
Blue
Green/Yellow
Green/Yellow
Green
Table 18 Wiring to Motors
Note:
On models AR-20xE and AR-30xE, the Motor Brake Relay is on a
separate connector. See Figure 22 on page
Note:
See additional warning on next page.
Warning —
You must connect the Motor Safety Earth conductor terminal,
marked with the earth symbol , to the motor cable’s motor-safety-earth wire
(green/yellow).