Tdtemp, Terrlg – Parker Hannifin 88-021610-01G User Manual
Page 148
Parker Hannifin
148 Aries User Guide
TDTEMP
Transfer Drive Temperature
Type
Transfer
Product Rev
Syntax
Aries 1.0
Units
Degrees Celsius
Range
N/A
Default
N/A
Response
TDTEMP: <*>5Ø
See Also
The TDTEMP reports the measured temperature (internal) of the drive.
TERRLG
Transfer Error Log
Type
Transfer
Product Rev
Syntax
Aries 1.0
Units
N/A
Range
N/A
Default
N/A
Response
TERRLG: <*>Operating hours: 1Ø5.25
<*>Power on Time: 5hrs 1Ø min 45.35 s
<*>Drive Temp: 35C
<*>Motor Temp: 85C
<*>Bus voltage: 163V
<*>Command Voltage: 5.35V
<*>Active Errors: E26-Drive Faulted
E27-Bridge Hardware Fault
<*>[Power Cycle]
See Also
,
,
,
The error log is updated every time an error occurs or the power is cycled.
The TERRLG command displays the last ten error conditions or power cycles.
The command displays them in order of earliest to latest, and returns a text-
based status report. When each error is logged, the following parameters are
saved:
• Operating
Hours
(TDHRS, TDMIN, TDSEC)
• Power-on
Time
• Drive Temperature (TDTEMP)
• Motor Temperature (TMTEMP)
• Bus Voltage (TVBUS)
• Command Voltage (TANI)
• Active
Errors
(ERROR)
The CERRLG command erases the stored contents of the error log. Clearing
the error log is a helpful diagnostic tool; it allows you to start the diagnostic
process when the error log is in a known state so that you can check the
error log in response to subsequent events.