148 Aries User Guide

TDTEMP

Transfer Drive Temperature

Type

Transfer

Product Rev

Syntax

TDTEMP

Aries 1.0

Units

Degrees Celsius

Range

N/A

Default

N/A

Response

TDTEMP: <*>5Ø

See Also

STATUS

,

TERRLG

The TDTEMP reports the measured temperature (internal) of the drive.

TERRLG

Transfer Error Log

Type

Transfer

Product Rev

Syntax

TERRLG

Aries 1.0

Units

N/A

Range

N/A

Default

N/A

Response

TERRLG: <*>Operating hours: 1Ø5.25

<*>Power on Time: 5hrs 1Ø min 45.35 s
<*>Drive Temp: 35C
<*>Motor Temp: 85C
<*>Bus voltage: 163V
<*>Command Voltage: 5.35V
<*>Active Errors: E26-Drive Faulted

E27-Bridge Hardware Fault

<*>[Power Cycle]

See Also

CERRLG

,

CONFIG

,

ERROR

,

ERRORL

,

OHALL

,

TANI

,

TDHRS

,

TDMIN

,

TDSEC

,

TDTEMP

,

TMTEMP

,

TVBUS

The error log is updated every time an error occurs or the power is cycled.
The TERRLG command displays the last ten error conditions or power cycles.

The command displays them in order of earliest to latest, and returns a text-
based status report. When each error is logged, the following parameters are
saved:

• Operating

Hours

(TDHRS, TDMIN, TDSEC)

• Power-on

Time

• Drive Temperature (TDTEMP)
• Motor Temperature (TMTEMP)
• Bus Voltage (TVBUS)
• Command Voltage (TANI)
• Active

Errors

(ERROR)

The CERRLG command erases the stored contents of the error log. Clearing

the error log is a helpful diagnostic tool; it allows you to start the diagnostic
process when the error log is in a known state so that you can check the
error log in response to subsequent events.