beautypg.com

Parker Hannifin 88-021610-01G User Manual

Page 71

background image

Parker Hannifin

Chapter 3 Electrical Installation 71

Inputs—Step & Direction

Description

Min

Typical

Max

Units

Common Mode Range

-7

+7

V

Differential Threshold Voltage

-200

+200

mV

Differential Termination
Impedance

120

ohms

Input Frequency (pre-quadrature)

5

MHz

Note:

All parameters are at the connector pin.

Table 33 Inputs—Step & Direction Electrical/Timing Characteristics

Inputs—Analog

Description

Min

Typical

Max

Units

Function Input Range

-10

+10

V

Resolution

14

bits

Impedance

>20

K ohms

Note:

All parameters are at the connector pin.

Table 34 Inputs—Analog Electrical/Timing Characteristics

Connector Specification—Aries Drive

Manufacturer ........................................... KYCON or equivalent

Connector Type....................................... 26-Pin High Density

D-Subminiature
(female socket)

KYCON Part Number.............................. K66-A26S-NR

Connector Specification—Mating Connector

Mating connectors are not provided with Aries drives. Parker cables are
available with mating connectors attached.

Manufacturer ........................................... AMP or equivalent

Connector Type....................................... 26-Pin High Density D-Subminiature

(male connector)

Cable Kit.................................................. AMP Part Number 748474-1

Includes: 748365-1 connector,
shield, enclosure, and two jack
screws (does not include contacts or
ferrules)

Contacts .................................................. Crimp style

30µ” Gold—AMP Part Number
748333-4
Gold Flash—Amp Part Number
748333-7