Table 51 configuring hall sensors – Parker Hannifin 88-021610-01G User Manual

Page 167

background image

Parker Hannifin

Chapter 7 Troubleshooting 167

Phase

Hall State

U

V

W

Correct

Use SHALL1

+

1

6

+

+

5

2

+

4

3

+

+

6

1

+

2

5

+

+

3

4

Table 51 Configuring Hall Sensors

Figure 50 illustrates the alignment of phases U, V, and W with Halls 1, 2, and
3 as viewed from the front of the shaft. The illustration assumes the following:

• Hall signals that are High equal

TRUE

signals.

• Hall 1 is the least significant bit (LSB).
• Hall 3 is the most significant bit (MSB).
• There is one hall cycle and one electrical cycle per pole pair on the

motor.

Figure 50 Motor Terminal Voltages (back EMF) and Hall Sensor Signals