Igain, Iauto, Inpos – Parker Hannifin 88-021610-01G User Manual
Page 134
Parker Hannifin
134 Aries User Guide
Sending an IANI1 command inverts the input polarity. In addition, the
command TANI reflects this change.
IAUTO
Automatically determine Current Loop Gains
Type
Tuning
Product Rev
Syntax
Aries 3.0
Units
none
Range
0 (disable) or 1 (enable)
Default
1
Response
IAUTO: <*>1
See Also
The IAUTO command allows the drive to automatically determine the current
loop gains according to the bandwidth set via the DIBW command, and the
motor parameters (Resistance and Inductance). This can give improved
current loop response compared to using the default gains set by the support
tool.
IGAIN
Integral Gain
Type
Tuning
Product Rev
Syntax
Aries 1.0
Units
none
Range
Ш.ШШ to 1ШШ.ШШ
Default
1
Response
IGAIN: <*>1.ØØ
See Also
The IGAIN command sets the integral gain of the current loop. High gains
can emphasize resonance and system noise, adds to heating of both motor
and drive, and increases acoustic noise produced by the motor.
INPOS
Enable In Position Output
Type
Drive Configuration
Product Rev
Syntax
Aries 2.0
Units
b = enable bit
Range
Ø (disable) or 1(enable)
Default
Ø
Response
INPOS: <*>Ø
See Also
Use the INPOS command to replace the Fault output with an In-Position
output when using the drive in step & direction modes (DMODES6 and 7). If