beautypg.com

Table 6 ar-02xx power dissipation, Ar-08xx – Parker Hannifin 88-021610-01G User Manual

Page 24

background image

Parker Hannifin

24 Aries User Guide

Figure 1 Cabinet Losses for AR-02xx when connected to a Parker BE231D motor

Shaft Power

Voltage

0W*

20W

200W

120 VAC

15W

25W

34W

240 VAC

32W

44W

47W

* Drive enabled, zero torque.

Table 6 AR-02xx Power Dissipation

AR-08xx

The power dissipation in Table 7 for the AR-08xx has been measured using
the Parker BE343J motor.