Table 17 contains the continuous and peak output power ratings for all Aries
drive models.
Continuous Output
Peak Output
Drive
Current (Amps,
RMS)
Shaft Power*
(Watts, max)
Current
(Amps, RMS)
Shaft Power
(Watts, max)
AR-01xx
1.0
100
3.0
300
AR-02xx
1.75
200
5.25
600
AR-04xx
3.0
400
9.0
1200
AR-08xx
4.5
750
13.5
2250
AR-13xx
6.3
1300
14.1
3900
AR-20xE
10
2000
30
6000
AR-30xE
16
3000
48
9000
* Maximum shaft power rating at 240 VAC
Table 17 Output Power-Continuous and Peak
Motor Connector
AR-01xx, AR-02xx, AR-04xx,
AR-08xx, AR-13xx
Connector Type.......................................Removable screw terminal
Terminals ........................................6
Pitch ................... 0.200 in (5.08 mm)
Wire range .....................12-26 AWG
.......................................14-27 SWG
................................(0.12-3.30 mm
2
)
Wire strip length...... 0.310 in (8 mm)
Torque....7.0 in–lbs nom. (0.79 N-m)
AR-20xE, AR-30xE
Connector Type.......................................Non-Removable screw terminal
Terminals ......................................10
Pitch ........................ 0.315 in (8 mm)
Wire range .....................10-22 AWG
.......................................12-23 SWG
....................................(0.5-4.0 mm
2
)
Wire strip length..... 0.25 in (6.5 mm)
Torque....7.0 in–lbs nom. (0.79 N-m)