Parker Hannifin Dynaserv G2 User Manual
Page 61

5-7
[Hardware zero signal type]
#
318 value
<
0.05*#358 value
error
0.05*#358 value
≦
#
318 value
<
0.1 *#358 value
warning
0.1 *#358 value
≦
#
318 value
≦
0.7 *#358 value
normal
0.7 *#358 value
<
#
318 value
≦
0.75*#358 value
warning
0.75*#358 value
<
#
318 value
error
[Software zero signal type]
#
318 value
<
0.05*#358 value
error
0.05*#358 value
≦
#
318 value
<
0.1 *#358 value
warning
0.1 *#358 value
≦
#
318 value
≦
0.4 *#358 value
normal
0.4 *#358 value
<
#
318 value
≦
0.45*#358 value
warning
0.45*#358 value
<
#
318 value
error
5