beautypg.com

Specifications – Parker Hannifin Dynaserv G2 User Manual

Page 141

background image

11-6

Specifications

11

(3) DR/5000 Series Motor

5000 E Series

5000 B Series

Item

Unit

DR5100E

00*1

DR5070E

00*1

DR5070B

00*1

DR5050B

00*1

DR5030B

00*1

Maximum output torque

N

⋅m (kgf⋅m)

100 (10)

70 (7.0)

70 (7.0)

50 (5.0)

30 (3.0)

Rated number of revolutions
(100/200V)

rps

/2.0

/4.0

Encoder resolution

p/rev

638,976

557.056

Repeatability
accuracy

Sec

±4

±5

Motor

+

driver Rotational

positioning

Absolute accuracy

Sec

±90

±90

Rotor inertia

kg

⋅m

2

125 x 10

-3

100 x 10

-3

37 x 10

-3

34 x 10

-3

27 x 10

-3

Positive

4 x 104

4

(4 x 10

3

)

3 x 10

4

(3 x 10

3

)

Allowable axial
load

Negative

N (kgf)

2 x 10

4

(2 x 10

3

)

1 x 10

4

(1 x 10

3

)

Allowable moment load

N

⋅m (kgf⋅m)

400 (40)

200 (20)

Positive

2 x 10

-6

(2 x 10

-5

)

3 x 10

-6

(3 x 10

-5

)

Axial displacement
rigidity

Negative

mm/N

(mm/kgf)

3 x 10

-6

(3 x 10

-5

)

4 x 10

-6

(4 x 10

-5

)

Moment displacement rigidity

rad/ N

⋅m

(rad/kgf

⋅m)

4 x 10

-7

(4 x 10

-6

)

2 x 10

-6

(2 x 10

-5

)

Mass

kg

32

26

18.0

16.0

13.5

Motor

Height (refer to dimension diagram)

mm

243

210

240

212

184

(4) Motor Environment Specification

Motor

Comment

Temperature 0 to 45

°C

Ambient
operating
conditions Humidity

20 to 85%
R.H

Should have no
condensation.

Temperature -20 to 85

°C

Ambient
storage
conditions Humidity

20 to 85%
R.H

Should have no
condensation.

Operating environment

No corrosive gases and dust
should be present.

(5) Driver Part (General Specifications)

Type

500W type

2kW type

Model name

U!!!!!!!A!-*!!_
U!!!!!!!B!-*!!_

U!!!!!!!K!-*!!_

U!!!!!!!L!-*!!_

Input power supply voltage

100 to 115V

AC

+ 10%, -15%

50Hz/60Hz

200 to 230V

AC

+ 10%, -15%

50Hz/60Hz

100 to 115V

AC

+ 10%, -15%

50Hz/60Hz

200 to 230V

AC

+ 10%, -15%

50Hz/60Hz

100 to 115V

AC

+ 10%, -15%

50Hz/60Hz

200 to 230V

AC

+ 10%, -15%

50Hz/60Hz

Maximum current
consumption (KVA)

0.8

3.4

3.4

Ambient operating air
temperature and humidity

0 to 50

°C, 20 to 90% RH, without condensation

Ambient storage air
temperature and humidity

-20 to 85

°C, 20 to 90% RH, without condensation

Operating environment

No corrosive gases and dust should be present.

Mass (kg)

1.7

3.6

3.2

*

Input voltage 100 to 115V AC: 1, 200 to 230V AC: 2

Note: The 20A-type driver requires the derating as indicated in the figure above for the current square duty,

depending on the ambient temperature during operation. (For motors of DM1000A series, DR1000A series,
DR1000E series, and DR5000E series)

10%

20%

30%

40%

50%

25%

45%

0%

0℃

20℃

10℃

Ambient operating air temperature

30℃

40℃

50℃

60℃

Current derating curve

(2kW driver only)

Square current duty