beautypg.com

Connection and wiring, 7 wiring of sensor brake terminal – Parker Hannifin Dynaserv G2 User Manual

Page 34

background image

3-10

Connection and Wiring

3

3.7

Wiring of Sensor Brake Terminal

Pin #

Signal name

1 COMP0

2 XORG

3 XOTD

4 XOTU

5 (NC)

6 XBRKP

7 XBRKN

10mm

1) Push down the lever with

a screwdriver.

2) Insert the wire deeply.

3) Push up the lever

(until you hear the click)

Pin #

7

6

5

4

Signal

name

XBRKN

XBRKP

(NC)

XOTU

3

2

XOTD

XORG

1

COMP0

The recommended sensor logic is B contact.
Set the sensor to OFF when the light is shielded. The sensor described above will be set to OFF when the light is shielded
by the following result.

Home position sensor

(-) Over travel

(+) Over travel

DC power
supply

1

2

3

4

1

2

3

4

1

2

3

4

+

-

Example of sensor connection (sensor: EE-SX670 manufactured by Omron)

Rated voltage

Input specifications

12~24VDC (±10%)

Rated input
current

4.1 mA/point (at 12 VDC)
8.5 mA/point (at 24 VDC)

Input
impedance

3.0kΩ

Operating voltage
(relative to COMP*)

At OFF: 3.0 VDC or less
At ON: 9.0 VDC or more

Allowable

leakage current

OFF is guaranteed at 1.0
mA or less.

470Ω

2.7kΩ

COMP0

XORG

XOTD
XOTU

100kΩ

10kΩ

0.01μF

Vcc

PS2805

[Electrical specifications]

Electric wire
specification

!

0.3 to 0.75 mm

2

, electric wire coating with 10 mm of the core

exposed at the tip

!

If a twisted wire is used, the diameter of the strand should be
φ 0.18 or larger.

See the panel surface of the driver for the pin numbers.

Made by Sato Parts (ML1900H)