2 cable specification list – Parker Hannifin Dynaserv G2 User Manual
Page 27
3-3
3.2
Cable Specification List
Cable name
Electric cable size
Driver
Current (A)
1)
AC power supply
cable
2.0 mm
2
or more, 30 m or less in length
TB1
*
2)
Ground cable (power
supply)
2.0 mm
2
or more
TB1
*
3)
Motor cable
2.0 mm
2
or more, 30 m or less in length
TB1
*
4)
Sensor brake cable
0.3 to 0.75 mm
2
TB2
5)
RS232C
communication cable
Dedicated cable is required.
CN1
6)
Encoder resolver
cable
0.2mm
2
twisted pair, batch shielded cable, outer
diameter
φ 14 mm or less, 10 m or less in length
CN2
Maximum
100 mA DC
7)
Jumper cable
2.0 mm
2
or more
TB1
*
8)
Analog monitor card
Dedicated cable is required. [R7033YB] (cable
with connector)
CN3
9)
Controller cable
0.2 to 0.5mm
2
, batch shielded cable, outer
diameter
φ 9 mm or less, 3 m or less in length
CN4
Maximum
500 mA DC
*
20A for the A (
φ 264mm) and E (φ 205mm) types for both the DM and DR series
15A for the B (
φ 160mm) type, and 10A for the DM1004B/1004C motors
3