beautypg.com

Parameter details – Parker Hannifin Dynaserv G2 User Manual

Page 153

background image

Parameter details

STD1

1

Enables the over-travel error function in the + direction

Always

Minimum value: 0
Maximum value: 1
Initial value:

0

Unit:

None

Long:

Short:

+HOT_ErrorEnable

+HOT_ErrEn

Specify whether or not to enable an error when the over-travel signal in the + direction is detected while commanding to
move the axis in the + direction.

0: Does not enable an error.
1: Enables an error.

2

Enables the over-travel error function in the - direction

Always

Minimum value: 0
Maximum value: 1
Initial value:

0

Unit:

None

Long:

Short:

-HOT_ErrorEnable

-HOT_ErrEn

Specify whether or not to enable an error when the over-travel signal in the - direction is detected while commanding to
move the axis in the - direction.

0: Does not enable an error.
1: Enables an error.

4

Selecting the acceleration type

Always

Minimum value: 0
Maximum value: 1
Initial value:

0

Unit:

None

Long:

Short:

AccProfeel

AccProfeel

Select the acceleration type during trapezoidal move.

0: Constant acceleration
1: S shaped

5

Selecting the deceleration type

Always

Minimum value: 0
Maximum value: 1
Initial value:

0

Unit:

None

Long:

Short:

DecProfeel

DecProfeel

Select the deceleration type during trapezoidal move.

0: Constant deceleration
1: S shaped

7

Acceleration time during a trapezoidal move

Always

Minimum value: 1
Maximum value: 9999
Initial value:

1000

Unit:

msec

Long:

Short:

TaccTrapezoid

TaccTrapez

Specify the acceleration time required for velocity change for the maximum velocity during trapezoidal move.

8

Deceleration time during a trapezoidal move

Always

Minimum value: 1
Maximum value: 9999
Initial value:

1000

Unit:

msec

Long:

Short:

TdecTrapezoid

TdecTrapez

Specify the deceleration time required for velocity change for the maximum velocity during trapezoidal move.