Technical Specifications
A-3
Mobile Computer Technical Specifications
The following table summarizes the mobile computer’s intended operating environment.
Table A-1. Mobile Computer Technical Specifications
Operating Temperature
MC9000-G Series and MC9000-G RFID
(color and monochrome units)
-4° to 122° F (-20° to +50° C)
Storage Temperature
(color and monochrome units)
-40° to 158° F (-40° to +70° C)
Battery Charging Temperature
Batteries must be charged within the 32° to 104° F (0° to +40° C) ambient
temperature range.
Humidity
5% to 95% non-condensing
Electrostatic Discharge (ESD)
+/-15 kVDC (air); +/- 8 kVDC (contact)
Drop to Concrete
MC9000-G Series
(color and monochrome units)
6' (1.8 meters) at - 4° F to 122° F (-20° C to 50° C)
MC9000-G RFID
(monochrome units)
6' (1.8 meters) at -13° to 122° F (-25° to +50° C)
(color units)
6' (1.8 meters) at 14° to 122° F (-10° C to +50° C)
Sealing
IP64 (electronic enclosure)
Dimensions
MC9000-G Series
9.2 in. L x 3.6 in. W x 7.6 in. H
(233.7 mm L x 91.4 mm W x 193 mm H)
MC9000-G RFID
10.75 in. L x 7.7 in. H
Maximum width (antenna area): 4.7 in.
Minimum width (keyboard area): 2.5 in.
(273.05 mm L x 195.58 mm H)
(antenna area: 119.38 mm W)
(keyboard area: 63.5 mm W)