beautypg.com

Table, Table 3-8. laser scanner reader parameters – Symbol Technologies MC9000-G User Manual

Page 154

background image

MC9000-G Product Reference Guide for Embedded Windows® CE .NET

3-60

Table 3-8. Laser Scanner Reader Parameters

Reader
Parameters

Laser Values

Description

Reader Type

Laser

Laser type scan engine is used.

Aim Type

Trigger, Timed hold,
Timed Release

Trigger mode: On/off controlled by the trigger.

Trigger hold mode: Trigger scan be released but it remains active for the
specified period of time.

Timed release mode: Activation stops after a specified period of time, even if
the trigger is held.

Aim Duration 0-60,000 ms

Sets the Aim Duration time duration (0-60,000 ms in increments of 100 ms).

Aim Mode

Dot, Slab, Reticle, None Use only None (no aiming) or Slab (slab aiming).

Beam Width

Normal, Narrow

Sets the Beam Width duration to normal or narrow.

Raster Mode Smart, Cyclone, None,

Always Open,

Raster Mode, is not supported.

Beam Timer

0-60,000 ms

Sets the maximum amount of time that the laser remains on (0-60,000 ms in
increments of 100 ms). A value of 0 sets the laser to stay on.

Control LED

False, True

Control LED is not supported.

LED Level

High, Low

LED Level is not supported.

Class 1 Sup

False, True

Class 1 Sup is not supported.

Redundancy

None, Bidirectional

Sets the read direction for the barcode redundancy. Bidirectional reads in both
directions.

Linear Sec

All codes *2

All codes *3

Long*2, Short*3

Short, Redun

Short, Codabar

Sets the number of times a barcode is re-read to confirm an accurate decode.

All codes *2 : Two times read redundancy for all bar codes.

All codes *3 : Three times read redundancy for all bar codes.

Long *2 Short *3: Two times read redundancy for long bar codes, three times
for short bar codes.

Short, Redun: Two times read redundancy based on redundancy flags and
code length.

Short, Codabar: Two times read redundancy if short bar code or CODABAR).

Pointer Timer 0-60,000 ms

Sets the maximum amount of time that the pointer remains on (0-60,000 ms
in increments of 100 ms). A value of 0 sets the pointer to stay on.

Raster
Height

0-100 in increments of
5 in.

Raster Height is not supported.