Signals and wiring – MITSUBISHI ELECTRIC MR-J2S- CP User Manual
Page 89
3 - 40
3. SIGNALS AND WIRING
3.11.2 For the servo amplifier produced earlier than Dec. 2005
1) Termination of the cables
Solid wire: After the sheath has been stripped, the cable can be used as it is.
Approx. 10mm
(0.39inch)
Twisted wire: Use the cable after stripping the sheath and twisting the core. At this time, take
care to avoid a short caused by the loose wires of the core and the adjacent pole.
Do not solder the core as it may cause a contact fault. Alternatively, a bar
terminal may be used to put the wires together.
Cable size
Bar terminal type
[mm
2
] AWG
For 1 cable
For 2 cables
Crimping tool
Manufacturer
1.25/1.5 16 AI1.5-10BK AI-TWIN
1.5-10BK
2/2.5 14
AI2.5-10BU
CRIMPFOX ZA3
or
CRIMPFOX UD 6
Phoenix Contact
2) Connection
Insert the core of the cable into the opening and tighten the screw with a flat-blade screwdriver
so that the cable does not come off. (Tightening torque: 0.3 to 0.4N m (2.7 to 3.5Ib in)) Before
inserting the cable into the opening, make sure that the screw of the terminal is fully loose.
When using a cable of 1.5mm
2
or less, two cables may be inserted into one opening.